Reliability of infrared thermal imaging in evaluating the degree of stellate ganglion block
-
摘要: 目的 评价红外线热成像技术应用于评估星状神经节阻滞程度的可靠性。 方法 选择2015年11月-2016年11月于嘉兴市第一医院诊治的36例主观性耳鸣患者为研究对象,在超声引导下行患侧星状神经节阻滞术,观察疗效指标(G值):痊愈(记4分),耳鸣完全消失;显效(记3分),耳鸣程度明显缓解;有效(记2分),耳鸣程度轻度缓解;无效(记1分),耳鸣程度无缓解或加重。上睑下垂程度(L值):显著(记3分),可观察到明显上睑下垂;轻微(记2分),可观察到轻微上睑下垂,但不明显;无变化(记1分),对比两侧无上睑下垂。使用红外线热成像仪记录术前及术后10 min患者头面部红外线热成像图。测量面部两侧对称区域温差最大处记录为ΔT。疗效指标G值分别与上睑下垂程度L值及术后面部两侧对称区域最大温差ΔT(℃)行直线相关性分析。 结果 疗效指标:痊愈10人,显效17人,有效7人,无效2人,G值为(2.97±0.85)分;上睑下垂程度:显著7人,轻微17人,无变化12人,L值为(1.92±0.73)分;术后ΔT为(1.27±0.51)℃。L值与G值的相关系数为0.037,P>0.05,差异无统计学意义;术后ΔT与G值的相关系数为14.016,P<0.05,差异有统计学意义。 结论 霍纳综合征并不能客观的评价星状神经节阻滞的程度,而通过红外线热成像分析术后面部温差来评价星状神经节阻滞程度是可靠有效的。Abstract: Objective To evaluate the reliability of infrared thermal imaging techniques for assessment of stellate ganglion block. Methods Total 36 patients with subjective tinnitus in our hospital were chosen as the research objects. A stellate ganglion block was performed in affected side under the guidance of ultrasound. The therapeutic effect (G) was recorded as:cure (4 points):tinnitus disappeared; significant (3 points):tinnitus alleviated dramatically; effective (2 points):minimal response; invalid (1 point):no remission or exacerbation. The degree of blepharoptosis (L):significant (3 points):can be observed to significantly ptosis; minor (2 points):to slight ptosis can be observed, but not obvious; invalid (1 point):no ptosis by comparison of left and right sides. Infrared thermal imaging instrument was used to record the face infrared thermal imaging of patients before operation (Picture 1) and 10min after operation (Picture 2). The maximum temperature difference between the symmetry facial regions was recorded as ΔT. Linear correlation of G value with L value and ΔT (℃) was analyzed. Results The therapeutic effect:cure 10/36, significant 17/36, effective 7/36 and invalid 2/36, the G w value as 2.97±0.85; The degree of upper eyelid droop (L):significant 7/36, minor 17/36 and invalid 12/36, the L value was 1.92±0.73; Postoperative ΔT was (1.27±0.51)℃. There was no correlation between value G and value L, and the correlation coefficient was 0.037 (P>0.05); There was correlation between value G and Δ T (℃), and the correlation coefficient was 14.016 (P<0.05). Conclusion Horner's syndrome cannot give an objective evaluation for the degree of stellate ganglion block; however, the infrared thermal imaging is an reliable and useful technique for assessment of the degree of stellate ganglion block.
-
Key words:
- Ultrasound-guided /
- Infrared /
- Thermal imaging /
- Stellate ganglion /
- Block
点击查看大图
计量
- 文章访问数: 316
- HTML全文浏览量: 42
- PDF下载量: 2
- 被引次数: 0