留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

超声萤火虫联合超微血管成像技术对比X线钼靶诊断乳腺疾病的价值

冯淑 李阳 靳鹏 汤晓敏 孙医学

冯淑, 李阳, 靳鹏, 汤晓敏, 孙医学. 超声萤火虫联合超微血管成像技术对比X线钼靶诊断乳腺疾病的价值[J]. 中华全科医学, 2021, 19(12): 2098-2101. doi: 10.16766/j.cnki.issn.1674-4152.002246
引用本文: 冯淑, 李阳, 靳鹏, 汤晓敏, 孙医学. 超声萤火虫联合超微血管成像技术对比X线钼靶诊断乳腺疾病的价值[J]. 中华全科医学, 2021, 19(12): 2098-2101. doi: 10.16766/j.cnki.issn.1674-4152.002246
FENG Shu, LI Yang, JIN Peng, TANG Xiao-min, SUN Yi-xue. Value of micropure combined with superb microvascular imaging compared with X-ray molybdenum target for the diagnosis of breast diseases[J]. Chinese Journal of General Practice, 2021, 19(12): 2098-2101. doi: 10.16766/j.cnki.issn.1674-4152.002246
Citation: FENG Shu, LI Yang, JIN Peng, TANG Xiao-min, SUN Yi-xue. Value of micropure combined with superb microvascular imaging compared with X-ray molybdenum target for the diagnosis of breast diseases[J]. Chinese Journal of General Practice, 2021, 19(12): 2098-2101. doi: 10.16766/j.cnki.issn.1674-4152.002246

超声萤火虫联合超微血管成像技术对比X线钼靶诊断乳腺疾病的价值

doi: 10.16766/j.cnki.issn.1674-4152.002246
基金项目: 

安徽省教育厅重点项目 KJ2020A0582

蚌埠医学院自然科学研究重点项目 BYKY2019113ZD

详细信息
    通讯作者:

    孙医学,E-mail:13309621158@163.com

  • 中图分类号: R445.1R737.9

Value of micropure combined with superb microvascular imaging compared with X-ray molybdenum target for the diagnosis of breast diseases

  • 摘要:   目的  探讨超声萤火虫成像联合超微血管成像检查对比X线钼靶检查技术在诊断乳腺良恶性疾病中的鉴别价值。  方法  选取2019年12月—2020年12月在蚌埠医学院第一附属医院治疗的女性乳腺疾病患者160例,其中良性病变为124例,恶性病变为36例。所有乳腺疾病患者均为单发病变,所有纳入的乳腺疾病患者均接受超声萤火虫成像联合超微血管成像检查及X线钼靶检查技术。以术后的病理结果为金标准,比较2种检查技术的诊断结果和在乳腺疾病中的诊断效能。  结果  160例乳腺疾病患者,超声萤火虫成像联合超微血管成像检查诊断检出率为97.2%,X线钼靶检查诊断检出率为77.8%,2组间差异有统计学意义(P < 0.05)。超声萤火虫成像联合超微血管成像检查技术诊断特异度为95.2%(118/124)、灵敏度为97.2%(35/36)、准确度为95.6%(153/160)均高于X线钼靶检查技术[特异度78.2%(97/124)、灵敏度77.8%(28/36)、准确度78.1%(125/160)],差异有统计学意义(χ2=15.415、4.571、21.487,均P < 0.05)。  结论  超声萤火虫成像联合超微血管成像检查技术诊断乳腺疾病的效能高于X线钼靶单项检查技术,有助于提高乳腺恶性肿瘤的诊断准确率。

     

  • 图  1  乳腺浸润性导管癌SMI成像图

    注:血流分级为Ⅱ级。

    图  2  乳腺浸润性导管癌SMI成像图

    注:血流分级为Ⅱ级。

    图  3  钙化灶的显示情况

    注:左侧为乳腺浸润性导管癌高频超声模式下钙化灶的显示情况,右侧为萤火虫成像模式下微钙化灶的显示情况。

    表  1  micropure联合SMI诊断乳腺疾病良恶性结果比较(例)

    病理检查 micropure联合SMI 合计
    良性 恶性
    良性 118 6 124
    恶性 1 35 36
    合计 119 41 160
    下载: 导出CSV

    表  2  X线钼靶诊断乳腺疾病良恶性结果比较(例)

    病理检查 X线钼靶 合计
    良性 恶性
    良性 97 27 124
    恶性 8 28 36
    合计 105 55 160
    下载: 导出CSV

    表  3  2种检测方法的特异度、灵敏度、准确度比较(%)

    项目 灵敏度 特异度 准确度
    Micropure联合SMI 97.2(35/36) 95.2(118/124) 95.6(153/160)
    X线钼靶 77.8(28/36) 78.2(97/124) 78.1(125/160)
    χ2 4.571 15.415 21.487
    P 0.033 < 0.001 < 0.001
    下载: 导出CSV
  • [1] REHBERG B, MATHIVON S, COMBESCURE C, et al. Prediction of acute postoperative pain following breast cancer surgery using the pain sensitivity questionnaire: A cohort study[J]. Clin J Pain, 2017, 33(1): 57-66. doi: 10.1097/AJP.0000000000000380
    [2] 王祥芝, 汤晓敏, 杨菊萍, 等. 数字乳腺断层摄影与MRI在乳腺良恶性疾病诊断中的比较[J]. 中华全科医学, 2021, 19(7): 1186-1190. https://www.cnki.com.cn/Article/CJFDTOTAL-SYQY202107031.htm
    [3] 罗青, 陈伟萍, 郭黎红, 等. 超声"萤火虫"联合超微血管成像技术校正BI-RADS 4级乳腺结节的临床价值[J]. 实用医学杂志, 2019, 35(15): 2474-2477. doi: 10.3969/j.issn.1006-5725.2019.15.026
    [4] 李茂谊, 罗琴音, 陈琛, 等. BI-RADS分类联合超微血管成像技术在乳腺实性结节鉴别诊断中的价值[J]. 中国现代医生, 2020, 58(4): 136-138. https://www.cnki.com.cn/Article/CJFDTOTAL-ZDYS202004050.htm
    [5] 姜玉新, 张运. 超声医学高级教程[M]. 北京: 中华医学电子音像出版社, 2016: 395-396.
    [6] 顾星. 超声"萤火虫"成像及常规高频超声在乳腺微钙化中的研究[J]. 南通大学学报(医学版), 2020, 40(1): 81-83. https://www.cnki.com.cn/Article/CJFDTOTAL-NTYX202001022.htm
    [7] GUO R, LU G, QIN B, et al. Ultrasound imaging technologies for breast cancer detection and management: A Review[J]. Ultrasound Med Biol, 2018, 44(1): 37-70. https://pubmed.ncbi.nlm.nih.gov/29107353/
    [8] 赵青, 纪甜甜, 赵献萍, 等. 超声与钼靶BI-RADS分类对不同直径乳腺肿块的诊断价值的对比研究[J]. 影像研究与医学应用, 2018, 2(6): 160-161. doi: 10.3969/j.issn.2096-3807.2018.06.094
    [9] BHELE S, STODDART L, PETERSEN C et al. Parasitic microcalcifications of the breast[J]. Int J Surg Pathol, 2020, 28(6): 645-646. doi: 10.1177/1066896919894687
    [10] HORVAT J V, KEATING D M, Rodrigues-Duarte H, et al. Calcifications at digital breast tomosynthesis: Imaging features and biopsy techniques[J]. Radiographics, 2019, 39(2): 307-318. doi: 10.1148/rg.2019180124
    [11] 吴水才, 欧阳亚丽, 崔博翔, 等. 乳腺微钙化超声检测方法综述[J]. 北京工业大学学报, 2020, 46(2): 217-226. https://www.cnki.com.cn/Article/CJFDTOTAL-BJGD202002013.htm
    [12] 杨真露, 李嫣, 詹晨奥, 等. RSNA2020乳腺影像学[J]. 放射学实践, 2021, 36(3): 307-310. https://www.cnki.com.cn/Article/CJFDTOTAL-FSXS202103010.htm
    [13] 王月红, 温德惠, 刘翔宇, 等. 超声MicroPure成像技术联合mSMI对TI-RADS3、4级结节的鉴别诊断价值[J]. 临床耳鼻咽喉头颈外科杂志, 2017, 31(3): 180-184, 190. https://www.cnki.com.cn/Article/CJFDTOTAL-LCEH201703004.htm
    [14] RUAN W, HE Y, SHAO X, et al. The ability of micropure® ultrasound technique to identify microcalcifications in carotid plaques[J]. Clin Neurol Neurosurg, 2021, 201: 106401. doi: 10.1016/j.clineuro.2020.106401
    [15] YANG Y, MU T, LI T, et al. Effects of FSTL1 on the proliferation and motility of breast cancer cells and vascular endothelial cells[J]. Thorac Cancer, 2017, 8(6): 606-612. doi: 10.1111/1759-7714.12491
    [16] BARR R G, COSSROVE D, BROCK M, et al. WFUMB guidelines and recommendations on the clinical use of ultrasound elastography: Part 5. Prostate[J]. Ultrasound Med Biol, 2017, 43(1): 27-48. doi: 10.1016/j.ultrasmedbio.2016.06.020
    [17] CHEN L, ZHAN J, DIAO X H, et al. Additional value of superb microvascular imaging for thyroid nodule classification with the thyroid imaging reporting and data system[J]. Ultrasound Med Biol, 2019, 45(8): 2040-2048. doi: 10.1016/j.ultrasmedbio.2019.05.001
    [18] LIM A K P, SATCHITHANANDA K, DICK E A, et al. Microflow imaging: New doppler technology to detect low-grade inflammation in patients with arthritis[J]. Eur Radiol, 2018, 28(3): 1046-1053. doi: 10.1007/s00330-017-5016-4
    [19] STRAND F, HUMPHRAEYS K, ERIKSSON M, et al. Longitudinal fluctuation in mammographic percent density differentiates between interval and screen-detected breast cancer[J]. Int J Cancer, 2017, 140(1): 34-40. doi: 10.1002/ijc.30427
    [20] DIAO X, ZHAN J, CHEN L, et al. Role of superb microvascular imaging in differentiating between malignant and benign solid breast masses[J]. Clin Breast Cancer, 2020, 20(6): e786-e793. doi: 10.1016/j.clbc.2020.06.009
  • 加载中
图(3) / 表(3)
计量
  • 文章访问数:  249
  • HTML全文浏览量:  71
  • PDF下载量:  7
  • 被引次数: 0
出版历程
  • 收稿日期:  2021-08-04

目录

    /

    返回文章
    返回