Volume 17 Issue 8
Aug.  2022
Turn off MathJax
Article Contents
XU Fang-yuan, ZHU Yuan-zhen, WANG Hong, FANG Ping, WU Yi-qing, WU Peng-fei, ZHANG Mu-cheng, WANG Gen-he. Explore the normal range of intra-abdominal pressure with direct measurement and the relationship between ascites quantitation and intra-abdominal pressure[J]. Chinese Journal of General Practice, 2019, 17(8): 1317-1319,1343. doi: 10.16766/j.cnki.issn.1674-4152.000932
Citation: XU Fang-yuan, ZHU Yuan-zhen, WANG Hong, FANG Ping, WU Yi-qing, WU Peng-fei, ZHANG Mu-cheng, WANG Gen-he. Explore the normal range of intra-abdominal pressure with direct measurement and the relationship between ascites quantitation and intra-abdominal pressure[J]. Chinese Journal of General Practice, 2019, 17(8): 1317-1319,1343. doi: 10.16766/j.cnki.issn.1674-4152.000932

Explore the normal range of intra-abdominal pressure with direct measurement and the relationship between ascites quantitation and intra-abdominal pressure

doi: 10.16766/j.cnki.issn.1674-4152.000932
  • Received Date: 2018-09-08
  • Objective To explore the normal range of intra-abdominal pressure (IAP) using direct measurement, and discuss the relationship between ascites quantitation and intra-abdominal pressure. Methods A prospective cohort study was conducted. We acquire the normal range of IAP in patients without ascites using direct measurement. Meanwhile, we compared the IAP of ascites group with non-ascites group. Then, we injected different volume of normal saline containing chemotherapeutics drugs into the abdominal cavity of non-ascites, monitor the change of IAP, and found the relationship between them. Results ① The 95% confidence interval of the IAP measuring by direct measurement in non-ascites was 4.99-6.11 mm Hg (1 mm Hg=0.133 kPa). ②The IAP of non-ascites was significant lower than ascites group (t=-2.188, P=0.031). ③A significant linear correlation was observed between the volume of normal saline and IAP (R=0.113, t=5.206, P<0.01), the regression equation was Y=7.651X+1.491 (P<0.01). ④The range of IAP after injecting normal saline was 4-19 mm Hg. Among them, there were 52 between 12 and 15 mm Hg and 5 between 16 and 20 mm Hg. There were no patients between 21 and 25 mm Hg and >25 mm Hg. All the patients had no organ dysfunction or organ failure. Conclusion The normal range of IAP measuring by direct measurement is 4.99-6.11 mm Hg, which different from Kron technique in numerical, more studies are needed to explore the relation between them. An increase in ascites can lead the increase in IAP, and there is a linear correlation between them, so we should worry about intra abdominal hypertension (IAH) or abdominal compartment syndrome (ACS) when increase in ascites. The happen of ACS has relationship with the duration of high pressure caused by ascites, so reduce IAP timely has important significance in precention an treatment ACS.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (286) PDF downloads(1) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return