YU Bo, ZHU Bin, DU Qiong, YE Xuan, LIU Ying-ying, YOU Yu-fang, GUO Zi-han, GAO Fei-fei, ZHAI Qing. Evaluation of environmental contamination of centralized preparation of cytotoxic drugs and the application of closed-system drug transfer device[J]. Chinese Journal of General Practice, 2019, 17(12): 2123-2126. doi: 10.16766/j.cnki.issn.1674-4152.001143
Citation: YU Bo, ZHU Bin, DU Qiong, YE Xuan, LIU Ying-ying, YOU Yu-fang, GUO Zi-han, GAO Fei-fei, ZHAI Qing. Evaluation of environmental contamination of centralized preparation of cytotoxic drugs and the application of closed-system drug transfer device[J]. Chinese Journal of General Practice, 2019, 17(12): 2123-2126. doi: 10.16766/j.cnki.issn.1674-4152.001143

Evaluation of environmental contamination of centralized preparation of cytotoxic drugs and the application of closed-system drug transfer device

doi: 10.16766/j.cnki.issn.1674-4152.001143
  • Received Date: 2019-05-10
    Available Online: 2022-08-05
  • Objective To evaluate the effect of closed system drug transfer device (CSTD) on the residual amount of cytotoxic drugs in the pharmacy intravenous admixture services (PIVAS). Methods Using cyclophosphamide as an example drug, WIPE samples and High performance liquid chromatography (HPLC) are used to quantitatively detect the residual of cyclophosphamide in the PIVAS of Fudan University Shanghai Cancer Center. Three batches of samples were taken before and after-cleaning at the end of one working day of dispensing in a conventional formulation method, and also after three weeks of continuous application of CSTD for dispensing. The samples were taken from 19 positions including the working surfaces of three biological safety cabinet, transport cart and export table. The residual amount of cyclophosphamide in the three batches of samples was compared. Results The median value of monitoring points before decontamination was 1.30 (IRQ: 0.24, 2.60) ng/cm2, and the median value after decontamination was 0.22 (IRQ: 0.08, 0.53) ng/cm2. There were significant differences between before and after decontamination (P<0.001). After implementation in the CSTD, the median value of monitoring points before decontamination was 0.06 (0.02, 0.88) ng/cm2, which was significantly lower than that before the regular decontamination (P<0.001), and also lower than the after regular decontamination, but the difference was not significant (P=0.299). Conclusion The application of CSTD can effectively reduce environmental contamination of cytotoxic drug in the process of dispensing and transportation, thus significantly reduce occupational exposure to toxic drugs by relevant medical staff.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (211) PDF downloads(1) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return