Volume 14 Issue 9
Aug.  2022
Turn off MathJax
Article Contents
CHEN Song-kuan, YANG Guang-zhao, MAO Guo-qun, JIA Yu-zhu, ZHOU Yu-qi. Preliminary study of lung iodine map by dual-energy CT after inhalation of Iodine gas in rabbits[J]. Chinese Journal of General Practice, 2016, 14(9): 1540-1543. doi: 10.16766/j.cnki.issn.1674-4152.2016.09.036
Citation: CHEN Song-kuan, YANG Guang-zhao, MAO Guo-qun, JIA Yu-zhu, ZHOU Yu-qi. Preliminary study of lung iodine map by dual-energy CT after inhalation of Iodine gas in rabbits[J]. Chinese Journal of General Practice, 2016, 14(9): 1540-1543. doi: 10.16766/j.cnki.issn.1674-4152.2016.09.036

Preliminary study of lung iodine map by dual-energy CT after inhalation of Iodine gas in rabbits

doi: 10.16766/j.cnki.issn.1674-4152.2016.09.036
  • Received Date: 2016-03-18
  • Objective To study the feasibility of pulmonary ventilation imaging by dual-source CT(DSCT) after inhalation of Iodine gas in rabbits. Methods A total of 18 experimental rabbits were divided into group 1(1/3),group 2(1/2),and group 3(2/3) according to the proportion of inhaled Iohexol(300 mgI/ml) and normal saline,with 6 in each group.The intraperitoneal anesthesia was performed with 15% chloral hydrate (1 kg/ml) in a fasting state.The marginal ear vein was then opened.Sumianxin Ⅱ(1 kg/0.5 ml) was used for additional venous anesthesia in order to reach an ideal state.The iodine gas with different concentration was aerosol inhaled by the rabbits under anesthesia for DSCT scanning.After the post-processing of the DSCT images,the iodine imaging was obtained for the subjective and objective evaluation. Results The subjective rating of imaging qualities was consistently preferable(Kappa=0.786).The total scores in the three groups were 3.25±0.5,4.40±0.44,and 4.20±0.40,respectively.Group 2 had the highest total and subjective scores.The comparison of objective rating between group 1 and group 2 was statistically significant(P<0.05),while between group 2 and group 3 was not statistically significant (P>0.05).Group 2 (one iohexol plus two saline) was the best concentration for DSCT imaging;150 s,210 s and 270 s after the aerosol inhalation were the best phases for observation.The distribution of iodine in the lung was generally uniform for this group,with all pictures rating above 3. Conclusion It is feasible to study the rabbit pulmonary ventilation by aerosol inhaling iodine gas DSCT.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (148) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return