Volume 14 Issue 11
Aug.  2022
Turn off MathJax
Article Contents
SHI Chao, XU Jie, LI Chao-ding, YANG Liu-zhong, FENG Hu. Analyzing and preventing loose causes of early postoperative intervertebral fusion of lumbar disc herniation[J]. Chinese Journal of General Practice, 2016, 14(11): 1806-1809. doi: 10.16766/j.cnki.issn.1674-4152.2016.11.005
Citation: SHI Chao, XU Jie, LI Chao-ding, YANG Liu-zhong, FENG Hu. Analyzing and preventing loose causes of early postoperative intervertebral fusion of lumbar disc herniation[J]. Chinese Journal of General Practice, 2016, 14(11): 1806-1809. doi: 10.16766/j.cnki.issn.1674-4152.2016.11.005

Analyzing and preventing loose causes of early postoperative intervertebral fusion of lumbar disc herniation

doi: 10.16766/j.cnki.issn.1674-4152.2016.11.005
  • Received Date: 2016-07-22
  • Objective To investigate the causes and prevention methods of lumbar disc herniation after lumbar interbody fusion (within three months). Methods A retrospective analysis of 268 patients with lumbar disc herniation in the period from January,2007 to January,2014 was carried out in 10 patients with early stage interbody fusion and posterior decompression and interbody fusion. Ten cases of patients with early fusion cage loose clinical data were analyzed. The observation intervertebral fusion device loosening were age, activity time, interbody fusion device initial position, endplate disposition, additional disc space before graft, application of the cross connecting rod, infection and treatment of index were analyzed. Results Cases of intervertebral fusion device loose, patients aged 26 to 58 years, mean age 43.2 years;one month within the proportion of patients with 6 cases (60%);interbody fusion device initial position after partial with 4 cases (40%),plate processing bad with 7 cases (70%);no additional disc space before the patient's bone with 2 cases (20%);without the use of a transverse connecting rod accounted with 7 cases (70%);postoperative infection in 2 cases (20%). Conclusion These results indicate that younger patients,early activity and interbody fusion in poor initial location and endplate preparation adverse caused by intervertebral fusion device attached to the poor,no additional disc space before bad bone,without using a transverse connecting rod and infection may be caused by lumbar disc herniation surgery appears early intervertebral fusion device loosening.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (242) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return